VPI (Vacuum Pressure Impregnated) and CRT (Cast Resin) Transformer are most Popular Transformer due to Low Maintenance, Compact Size, High Efficiency and protecting from environmental exposure.
High-quality, High Grade void-free resin impregnation used in VPI (Vacuum Pressure Impregnated) Transformer give Superior mechanical and electrical insulation to meet Demanding applications, high temperatures and variable loads.
NK ELECTRO TRANS PRIVATE LIMITED Special Design VPI (Vacuum Pressure Impregnated) Transformer used in Superior Insulation to maintain Durability, Reduced Noise, Improved Heat Dissipation and Environmental Resistance
Rating: 250KVA to 2000KVA
Material: Copper or Aluminum
Voltage Ratio: 33KV, 22KV, 11KV, 6.6KV, 3.3KV
Frequency: 50Hz, 60Hz or Customer Specified
Off Load Step Down Distribution Transformer Tapping Range:
5tap, 7tap, 9tap, 17tap, Customer Specified insteps of HV 2.5%
Vector Group: All Vector Group (Dyn11, Dyn5 etc.)
Insulation Class: F Class
Inhouse Testing Facility: Up to 33KV
Durability, Reduced Noise, Improved Heat Dissipation and Environmental Resistance.
Low Power Loss, More Reliability and High Efficiency
Modern Technology with Follow Standard: IS-2026 Power Saving Transformer & IEC Standard
25 Years Trouble-free Performance
Design to withstand High Voltage, Double Voltage Double Frequency, Impulse, Thermal and Dynamic Stress
CRT (Cast Resin) Transformer are most Popular Transformer due to Low Maintenance, Compact Size, High Efficiency and protecting from environmental exposure.
Make Special Design of CRT (Cast Resin) Transformer NK ELECTRO TRANS PRIVATE LIMITED use Encapsulation in solid epoxy resin High Grade Composition material shell give Excellent encapsulation and environmental resistance to use in Harsh environments, high moisture, outdoor installations and give Robustness, Environmental Resistance, Safety and Easy Maintenance.
Rating: 250KVA to 2000KVA
Material: Copper or Aluminum
Voltage Ratio: 33KV, 22KV, 11KV, 6.6KV, 3.3KV
Frequency: 50Hz, 60Hz or Customer Specified
Off Load Step Down Distribution Transformer Tapping Range: 5tap, 7tap, 9tap, 17tap,
Customer Specified insteps of HV 2.5%
On Load Step Down Distribution Transformer Tapping Range: 9tap, 17tap, Customer
Specified insteps of HV 1.25%
Vector Group: All Vector Group (Dyn11, Dyn5 etc.)
Insulation Class: F Class
Inhouse Testing Facility: Up to 33KV
Robustness, Environmental Resistance, Safety and Easy
Maintenance.
Low Power Loss, More Reliability, High Efficiency
Modern Technology with Follow Design Standard: IS-2026
Power Saving Transformer & IEC Standard
25 Years Trouble-free Performance
Design to withstand High Voltage, Double Voltage
Double Frequency, Impulse, Thermal and Dynamic Stress
Compact Sub-Station (CSS)